Safety light curtains
C4000 Standard without extension connection

receiver
Type C40E-0903CA010
Part No. 1018644

sender
Type C40S-0903CA010
Part No. 1018643


At a glance
Type 4 (IEC 61496), PL e (EN ISO 13849)
7-segment display
PSDI mode with the UE402 switching amplifier
External device monitoring (EDM) and restart interlock (RES)
Configuration and diagnostics via PC
Cascade up to three systems
ADO (Application Diagnostic Output) signaling output for contamination indicator
Accessory Clone Plug - for configuration memory

Your benefits
7-segment display saves time during alignment and diagnostics
Beam coding protects the systems against opticalinterference by ensuring a high level of availability
Ability to cascade up to three systems optimizes the safety application and reduces wiring costs
Preconfigured light curtains and the clone plug enables easy and rapid commissioning
Precise, convenient configuration and diagnostics reduces downtime








Functions-Sender
Beam coding:
Reduced resolution: -
Configuration method: PC with CDS (Configuration and Diagnostic Software)
Extension connection: -
PSDI mode with: UE402
Safe SICK device communication via EFI/SDL:



Functions-Receiver
Restart interlock:
Restart interlock (delivery status): external
External device monitoring (EDM):
External device monitoring (delivery status): deactivated
Beam coding:
Beam coding (delivery status): non-coded
Reduced resolution: -
Bypass (with UE402):
Emergency stop / bypass at extension connection: -
Operating mode switching (with UE402):
PSDI mode with: UE402
Muting with: Flexi Classic
Configuration method: PC with CDS (Configuration and Diagnostic Software)
Extension connection: -
Safe SICK device communication via EFI/SDL:



Technical Data-Sender
Protective field height: 900 mm
Resolution: 30 mm
Housing length: 1,030 mm
Housing cross-section: 48 mm x 40 mm
Type: Type 4 (IEC 61496)
Safety integrity level: SIL3 (IEC 61508), SILCL3 (IEC 62061)
Category: category 4 (EN ISO 13849)
Performance level: PL e (EN ISO 13849)
PFHd: 1.5 * 1E-08
TM (mission time): 20 a
Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
Connection type: Hirschmann plug M26 x 11 + FE, straight
Connection type configuration connection: M8 x 4
Maximum connection cable cross-section: 0.75 mm²
Wave length: 950 nm
Protection class: III (EN 50178)
Enclosure rating: IP 65 (EN 60529)
Ambient operating temperature: 0 °C ... 55 °C
Vibration resistance (checked to): 5 g (IEC 60068-2-6)
Oscillation frequency from ... to: 10 Hz ... 55 Hz
Shock resistance: 10 g, 16 ms (IEC 60068-2-29)
Weight: 1,960 g



Technical Data-Receiver
Protective field height: 900 mm
Resolution: 30 mm
Scanning range from ... to: 0 m ... 19 m
Scanning range from ... to (delivery status): 0 m ... 6 m
Housing length: 1,030 mm
Housing cross-section: 48 mm x 40 mm
Type: Type 4 (IEC 61496)
Safety integrity level: SIL3 (IEC 61508), SILCL3 (IEC 62061)
Category: category 4 (EN ISO 13849)
Performance level: PL e (EN ISO 13849)
PFHd: 1.5 * 1E-08
TM (mission time): 20 a
Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
Response time without beam coding: ≤ 12 ms
Response time with beam coding: ≤ 18 ms
Maximum switching current: 500 mA
Wave length: 950 nm
Connection type: Hirschmann plug M26 x 11 + FE, straight
Connection type configuration connection: M8 x 4
Maximum connection cable cross-section: 0.75 mm²
Protection class: III (EN 50178)
Enclosure rating: IP 65 (EN 60529)
Ambient operating temperature: 0 °C ... 55 °C
Vibration resistance (checked to): 5 g (IEC 60068-2-6)
Oscillation frequency from ... to: 10 Hz ... 55 Hz
Shock resistance: 10 g, 16 ms (IEC 60068-2-29)
Weight: 1,990 g